Zeus Omega Hall Etkili Akım Sensörü — Alternatör Sürücü Modülü (AZHSADM)


Direct current sensing at the Alternatör Sürücü Modülü. No shunt required. Plugs into the Zeus Omega ADM for real-time alternator current data and enhanced system diagnostics. Part No: AZHSADM.

Fiyat
Fiyat bilgisi için iletişime geçin
Buradan Satın Al

Ürün Mare Marin web satış kataloğunda açılır; ürün kodunu seçerek devam edin.

Limited pre-sale availability. Estimated shipping begins July 31st, 2026. Reserve your kit now to secure inventory from the first production run.

Zeus Omega Accessory — Part No: AZHSADM
No Shunt Required.
Direct Current Sensing
at the Alternator.
The Zeus Omega Hall Etkili Akım Sensörü for the Alternatör Sürücü Modülü provides direct, accurate alternator current sensing without the installation complexity of a traditional shunt. Plug into the ADM. Done.
No Shunt Required
Faster Commissioning
Accurate SOC Monitoring
Real-Time Data to the ADM
Zeus Omega Hall Etkili Akım Sensörü for Alternatör Sürücü Modülü (AZHSADM)
Why Hall Effect
Accurate current data.
Without the shunt headache.

Traditional analog shunts require precise installation, careful calibration, and interrupt the main current path. The Zeus Omega Hall Etkili Akım Sensörü for the ADM uses Hall Effect sensing technology to measure alternator current accurately and feed that data directly into Zeus Omega's intelligent regulation and diagnostics — with none of the installation complexity.

The AZHSADM
Direct alternator current sensing at the drive module.

The AZHSADM plugs directly into the Zeus Omega Alternatör Sürücü Modülü and measures current output in real time. That data feeds directly into Zeus Omega's intelligent regulation system — improving state-of-charge accuracy and enabling more precise system diagnostics.

Because the sensor does not need to be installed in-line with the main current path, there is no need to interrupt the main conductor, size a shunt to your system, or go through a calibration process at commissioning. Install it, connect it, and you are done.

For the ADM
The AZHSADM connects to the Alternatör Sürücü Modülü and measures current at the alternator — right at the source.
For the Kontrol Modülü
The companion AZHSCM sensor connects to the Kontrol Modülü for battery or alternator current sensing at the CM. Available separately.
Use Both for Full System Visibility
For complete current monitoring across your Zeus Omega system, use the AZHSADM at the ADM and the AZHSCM at the Kontrol Modülü together.
Zeus Omega Hall Etkili Akım Sensörü for Alternatör Sürücü Modülü
No Shunt Required Current Sensing
Faster Installation & Commissioning
Accurate State-of-Charge Monitoring
Enhanced System Diagnostics
Why It Matters
Everything a shunt gives you.
None of what makes shunts painful.

No Shunt to Size

Traditional shunts must be sized to your system's maximum current. Hall Etkili Akım Sensörüs work across a wide current range without needing to be matched to your alternator output.

No Calibration

Analog shunts require calibration at commissioning. The AZHSADM connects to the ADM and is ready to measure — no calibration process required.

No Current Path Interruption

Shunts are installed in-line with the main current path. Hall Effect sensing does not interrupt the current path — nothing is in series with the main conductor.

Real-Time Alternator Data

Current data from the AZHSADM feeds directly into Zeus Omega's regulation system — improving the accuracy of charging decisions and diagnostics in real time.

Better SOC Monitoring

Accurate current sensing means more accurate state-of-charge monitoring — giving you a truer picture of where your battery bank actually stands.

Enhanced Diagnostics

With current data at the ADM, Zeus Omega can surface more detailed system diagnostics through the app — helping identify issues faster.

Zeus Omega Hall Etkili Akım Sensörü for Kontrol Modülü (AZHSCM)
Also Available
Add the Hall Etkili Akım Sensörü for the Kontrol Modülü.

The AZHSCM provides the same no-shunt current sensing capability at the Zeus Omega Kontrol Modülü — measuring battery or alternator current at the CM rather than at the ADM.

For complete current visibility across your Zeus Omega system, use both sensors together: AZHSADM at the Alternatör Sürücü Modülü and AZHSCM at the Kontrol Modülü.

Also Available

Hall Etkili Akım Sensörü — Kontrol Modülü

Shop Kontrol Modülü Sensor →
Zeus Omega Accessory
Works with the Zeus Omega Alternatör Sürücü Modülü.

The AZHSADM is an optional accessory for the Zeus Omega system. It connects to the Alternatör Sürücü Modülü (AZADM) and requires a Zeus Omega system to be installed and operational.

If you do not yet have a Zeus Omega system, start with the complete Zeus Omega Alternatör Kontrol Sistemi kit (AZOMEGA) — which includes the Kontrol Modülü, ADM, AZ CAN Cable, power connection, fuses, and Sıcaklık Sensörü.

Zeus Omega Kontrol Modülü and Alternatör Sürücü Modülü
Sorular
Sık Sorulanlar
What is the Zeus Omega Hall Etkili Akım Sensörü for the ADM? The AZHSADM is an optional accessory for the Zeus Omega system that provides no-shunt current sensing at the Alternatör Sürücü Modülü. It measures alternator current output in real time and feeds that data directly into Zeus Omega's intelligent regulation and diagnostics — without requiring a traditional analog shunt.
Do I need this sensor to use Zeus Omega? No. The AZHSADM is an optional accessory. Zeus Omega functions without it. The sensor adds no-shunt current sensing at the ADM, which improves state-of-charge monitoring accuracy and enables more detailed system diagnostics through the Zeus Omega app.
What is the difference between the AZHSADM and the AZHSCM? The AZHSADM connects to the Alternatör Sürücü Modülü and measures current at the alternator. The AZHSCM connects to the Kontrol Modülü and measures battery or alternator current at the CM. They serve different measurement points in the system and can be used independently or together for full system current visibility.
Why use a Hall Etkili Akım Sensörü instead of a shunt? Traditional shunts must be sized to your system's maximum current, installed in-line with the main current path, and calibrated at commissioning. Hall Etkili Akım Sensörüs do not interrupt the current path — no sizing is required, no calibration is needed, and installation is faster. The measurement accuracy is equally reliable.
Does this work with all Zeus Omega ADMs? The AZHSADM is designed for the Zeus Omega Alternatör Sürücü Modülü (AZADM). Contact ARCO Marine to confirm compatibility with your specific Zeus Omega system configuration before purchasing.
What Zeus Omega system do I need to use this sensor? You need a complete Zeus Omega system with at least one Alternatör Sürücü Modülü (AZADM) installed and operational. If you do not yet have a Zeus Omega system, start with the complete Zeus Omega Alternatör Kontrol Sistemi kit (AZOMEGA).
Can I use the AZHSADM and AZHSCM together? Yes. Using both sensors together gives you current monitoring at two points in the system — at the alternator via the ADM, and at the battery or alternator via the Kontrol Modülü. This provides the most complete picture of current flow across your Zeus Omega installation.
Kurulum desteğini nereden alabilirim? Contact the ARCO Marine team directly at sales@arcomarine.com or 1-800-722-2720 for compatibility questions and installation guidance.
ARCO Marine
Questions about the
Zeus Omega Hall Etkili Akım Sensörü?

Contact the ARCO Marine team to confirm compatibility with your Zeus Omega system or to place an order.

Manufactured by ARCO Marine, Inc. · 3921 W. Navy Blvd. Pensacola, FL 32507 · arcomarine.com